Fire alarm system:

Prometey-05

ААОТ.425523.110

Addressable fire alarm control panel

 

For cars

 

47 K car
61-779 car 

 

Purpose

 

Addressable fire alarm control panel (AFACP) together with combination smoke detectors "Agat-10" and input-output devices "Agat-12" is designed for installation in railway cars to determine the place of fire in early stages of its occurrence.

 

Functions

  • cyclic polling of combination smoke detectors "Agat" through the two-wire signal line
  • visual and audible alarm when it detects “fire” or “system failure” with indication of the date and place of their occurrence 
  • the signal line operation in loopback mode or loop mode, which saves working capacity of system in case of open or short circuit in the signal line
  • automatic tests on the performance of smoke detectors, the signal line and the detector
  • archiving of alarm messages with the time and date of their occurrence according to the indications of non-volatile inbuilt real-time clock
  • switching on and off any smoke detector, as well as any sensor, which is the part of the detector on signal from the control panel
  • possibility of transferring information to the top-level equipment through RS-485 interface (MODBUS protocol)
  • performing functions of the security and conductor call systems together with smoke detectors and passenger remote controls
  • control reliability of information transmitted through the signal line
  • the possibility to view analog parameters values measured by sensors of smoke detectors
  • automatic switching of fire extinguishing equipment when fire is detected in confined spaces

 

The design of FACP "Prometey-05" was carried out in accordance with the requirements of DSTU EN54, harmonized with the European standards EN54.

 

Technical characteristics

  • Input voltage range in DC mains, V: 35...150
  • Maximum power consumption, W:

- in standby mode -  10; 

- in fire and failure modes -  25

 

 

The number of combination smoke detectors in the signal line, pcs: 63


Overall dimensions, mm: 635 х 120 х 55
Weight of the panel, kg: 8

 

Operating conditions

 

Climatic version: UHL 3.1 (boreal climate) according to GOST 15150-69
Operating temperature range: -40 ° C... +50 ° C
The average service life is not less than 20 years

 

Consumers

 